System Overview
J4350 Power System
The J4350 Services Router uses either AC or DC power. The autosensing power
supply (see Fi
gure 2 or Figure 4) distributes the different output voltages to
the router c omponents according to their voltage requirements.
The power supply is fixed in the chassis, and is not field-replaceable. The AC power
supply has a single AC applia nc e inle t that requires a dedicated AC power feed. The
DC power supp
ly has a terminal b lock tha t provides a si ngle D C input (–48 VDC
andreturn)andrequiresadedicated15A(48VDC)circuitbreaker.
The J4350 AC-powered chassis has a power switch and does n ot in clude a power LED.
The J4350 DC-powered chassis includes a power supply LED located to the upper
right of the power supply connector. Table 11 describes the power supply L ED.
Table 11: Power Supply LED
State Description
Off Nopowerisflowingtothepowersupply.
Green
Power suppl
y is connected and power is flowing.
Yellow Power supply is connected, but the router is not powered on.
For information abou t site power preparations, see “Power Guideline s,
Requirements, and Specifica tio ns” on pa ge 74. For information about connecting
the router to p ower and ground, see “Connecting Power” on page 86.
J6350 Power System
TheJ6350ServicesRouteruseseitherACorDCpower.Youcaninstalloneortwo
autosensing, load-sha rin g power supplies at the bottom rear of the chassis, as shown
in Figure 3 or Figure 5. The power supplies distribute the different output voltages to
the router components, depending on their voltage requirements. Wh en two p ower
supplies are installed and operational, they automatically share the electrical load.
For full redundancy, two power supplies are required. If a power supply stops
functioning for any reason, the second power supply instantly begins providing
all the power the router needs for normal functioning. It can provide full power
indefinitely. Power supplies on the J6350 Services Router can be hot-swapped.
Each power supply has an LED located to the upper right of the power supply
connector. Table 11 describes the power supply LED.
For information abou t site power preparations, see “Power Guideline s,
Requirements, and Specifica tio ns” on pa ge 74. For information about connecting
the router to p ower and ground, see “Connecting Power” on page 86.
Power supplies on J6350 Services Routers are hot-removable and hot-insertable.
You can remove and replace a redundant power supply without powering down the
J4350 and J6350 Services Router Hardware Features 21