IDP 75, 250, 800, and 8200 Installation Guide
50 IDP 800 Technical Specifications
IDP 800 Technical Specifications
Tables 25–28 list the physical, AC power, power cord, and environmental technical
specifications for the IDP 800 sensor.
Table 25: Physical Specifications
Specification Value
Height 2 RU (2.9 inches)
Width 17 inches
Depth 20.5 inches
Weight 33.5 lbs
Table 26: AC Power Specifications
Specification Nominal Value Acceptable Range
AC input voltage 110/220 VAC, single phase 90 to 255 VAC
AC input line frequency 50/60 Hz 47 to 63 Hz
AC input current 4 A @ 110 VAC
2 A @ 220 VAC
Table 27: Power Cord Specifications
Country Specifications
United States and Canada UL-approved and CSA-certified
Flexible cord minimum spec: No. 18 (1.5 mm
2
), Type SVT
or SJT, 3-conductor
Current capacity of 10 A minimum
Earth-grounding attachment plug with NEMA 5-15P (10 A,
125 V) configuration
Table 28: Environmental Specifications
Specification Value
Operating environment 0 to 35
o
C (ambient)
Non-operating environment -10
o
to 70
o
C